Fire extinguishers: your legal obligations

Journalist, Cherry Park

Author Bio ▼

Cherry Park is an experienced freelance journalist and reporter who specializes in features, news, and news analysis, in print and online. She has written extensively in the areas of health and safety, fire safety, employment, HR, recruitment, rewards, pay and benefits, market research, environment, and metallurgy, and she also conducts research.
March 27, 2017

Sign up to free email newsletters

Download

Mobile access series #1: What you need to know

There are nearly 20,000 commercial fires in the UK each year, demonstrating the importance of taking fire prevention measures in business premises.

So, what are the legal obligations of building or business owners regarding fire extinguishers?

All fire safety legislation in England and Wales for non-domestic premises is covered by the Regulatory Reform (Fire Safety) Order 2005 (RRO), which states that appropriate fire-fighting equipment, including portable fire extinguishers, must be provided where there is any risk of fire.

The RRO states that business owners and managers as designated Responsible Persons (RP) are responsible for carrying out a fire safety risk assessment and implementing and maintaining a fire management plan.

Since the law is not prescriptive in many areas, the fire safety risk assessment is crucial, and applies to all businesses, however small. RPs should ensure staff are trained in extinguisher location and correct use, and hold fire drills and evacuation procedures. Failure to protect staff by providing appropriate equipment could lead to prosecution and refusal of insurance pay-outs, apart from injury and loss of life.

The provision and maintenance of fire extinguishers is also covered by BS5306, which gives guidelines as to which extinguishers to use where and on what type of fire, but also allows an element of choice.


Discover the latest innovation in fire protection – see live demonstrations of fire safety solutions at FIREX 2019

18-20 June 2019 – ExCeL London

Secure your free ticket >>


 

Fire and extinguisher categories

Currently, materials present in the area to be protected from fire in the UK can be divided into 6 categories of fire involving different substances:

  • Class A, combustible carbon-based solids eg paper, wood or textiles
  • Class B, flammable liquids eg paraffin, petrol, diesel or oil (but not cooking oil)
  • Class C, flammable gases, eg butane, propane or methane
  • Class D, burning metals, eg aluminium, lithium or magnesium
  • Fires caused by electrical equipment (indicated by an electric spark symbol and not the letter E)
  • Class F, fats and cooking oils.

It is very important that the right type for the risk, the business and the location are supplied. The following types of extinguishers can be used to quench the various types of fire:

  • Class A – water, water mist, foam, dry powder, wet chemical
  • Class B – water mist, foam, dry powder, CO2, some wet chemical
  • Class C – water mist, dry powder
  • Class D – specialist dry powder
  • Electrical – some water mist, some foam, CO2
  • Class F – water mist, wet chemical

How many fire extinguishers do I need?

The regulations state that a minimum of two Class A fire extinguishers on every floor of a building are needed, unless the premises are very small, in which case one may be acceptable. Three- or six-litre foam, or nine-litre water, are the most frequently found types, although others are likely to be needed as well, most commonly CO2 extinguishers for electrical fires.

All premises with electrical equipment (which covers most premises) must have at least 2kg CO2 extinguishers, 5kg if there is 415-Volt rated equipment.

The number required depends on the size of the area to be protected and whether the business is classed as low or high risk. As a basic rule of thumb, the floor area in square metres should be divided by 200 and rounded up to calculate how many nine-litre water or equivalent extinguishers are necessary.

If there is a sprinkler or automatic suppression system in place, fewer fire extinguishers may be required.

Where to put them

Fire extinguishers must be accessible and visible. Water-based and CO2 fire extinguishers should be located by exits and fire alarm call-points to encourage people to move away from the fire.

The 30-metre rule is useful – in a low risk workplace an employee should be within 30 metres of an appropriate extinguisher on any given level of the premises, meaning that the devices can be sited 60m apart.

Specialist extinguishers, such as dry powder for Class C fires in areas such as boiler rooms and wet chemical extinguishers for kitchens (Class F), should be positioned within easy reach of, but not too near, the specific fire hazard, eg the boiler or the deep fat fryer. CO2 extinguishers should be placed within server or plant rooms.

Extinguishers should either be fixed by brackets to the wall, or, if very heavy, attached to a rigid floor stand to discourage people from moving them. Heavier extinguishers should be fixed with the handle at a height of about 1 metre.

If they are not totally obvious, extinguishers must be clearly signposted with ID signs fixed to the stand or wall and directional arrows if necessary. ID signs explain the type of extinguisher and how and when to use them.

If they need to be sited outside, water and foam extinguishers can be purchased that contain an anti-freezing agent.

Commissioning

Fire extinguishers must be commissioned on site by a competent person – usually someone with the BAFE fire extinguisher or equivalent qualification from a third-party-certified fire protection company. This involves a thorough check to ensure they are fit for purpose. A certificate will be issued to prove their compliance with the regulations.

Servicing and maintenance

Extinguishers must be maintained in good working order. The RP should carry out monthly visual checks, but they must be serviced annually by a competent person. A basic service should include checking it is in date, hasn’t been tampered with, is in good working order, with correct weight and pressure and has the correct signage and positioning.

Advice should be given on refilling/replacement or any additional extinguishers needed and the service recorded on the service label on the side.

UK fire extinguisher regulations recommend that extinguishers should be replaced or given an extended service/overhaul every 5 years. CO2 extinguishers should be replaced every 10 years, unless they are damaged or have been discharged. No extinguisher must ever be more than 20 years old.

It is also a legal requirement to keep a permanent record of all servicing, maintenance and inspections of fire extinguishers.

INTRUDER ALARM INSTALLER SURVEY - chance to win a £100 Amazon voucher

Does your business install, integrate or maintain intruder alarm systems (or have plans to)? This Texecom-sponsored survey takes a few minutes to complete and enters you into a prize draw for a £100 Amazon voucher (or equivalent value in local currency). This survey will inform the findings of a forthcoming trend report published on IFSEC Global.

Related Topics

9
Leave a Reply

avatar
8 Comment threads
1 Thread replies
1 Followers
 
Most reacted comment
Hottest comment thread
9 Comment authors
Big burnsDavid TannerSqueelerElaine KellyJoanna Recent comment authors
  Subscribe  
newest oldest most voted
Notify of
Ian
Guest
Ian

“Regulatory Reform (Fire Safety) Order 2005 (RRO), which states that appropriate fire-fighting equipment, including portable fire extinguishers, must be provided where there is any risk of fire.” Is not correct.

The words “where necessary” are important.

I think we should have tougher laws on this matter and wonder if Dame Judith Hackitt might actually spot this weakness.

starflame
Guest
starflame

It is very important to protect the nature from fire so that we use the fire fighting equipment that provides from our site i.e starflame

charlie
Guest
charlie

HI i live on a park home site with 34 homes in total. On site we have 4 containers with 2 fire extinguishers in them at 4 outside locations. These bottles are service yearly. I found one alarm not working and after speaking to site owner I found out they do not inspect any extinguishers monthly.
Question should extinguishers be checked monthly and should site have a fire marshall.

Squeeler
Guest
Squeeler

Monthly checks are required with records should be carried out by RP… yearly safety checks have to be carried out by an accredited engineer and signed off and dated…

Dave Anderson
Guest
Dave Anderson

That is interesting that fire equipment should be maintained. Then they can stay in good working order. That is something I would want to have done sometime soon. https://www.northernfire.com.au/services

Joanna
Guest
Joanna

I have a small gym business , have all the necessary fire extinguishers in place but feel it is unnecessary to test them weekly but is it the law to do so as I am not sure

Elaine Kelly
Guest
Elaine Kelly

Are we required by law to inspect the fire extinguishers each month and keep records?

David Tanner
Guest
David Tanner

i have reported that there is a fire extinguisher cupboard being blocked by a fridge what regulations is this breaking?

Big burns
Guest
Big burns

Can a fire extinguisher legally be used to keep a door open?

Sign up to free email newsletters