steel structure architecture fire safetyThe use of steel in modern building design offers more flexible usage than ever before – but fire safety must not be compromised along the way.

Architects and design engineers can use cellular beams to great effect, for example. Sometimes left exposed as part of an aesthetic finish, they add to the fascination of tall, complex structures.

As design is pushed to the boundaries using steel in all its forms, so load-bearing equations can alter. As other considerations come to the fore the need for an appropriate level of fire safety becomes paramount.

Although fire deaths are falling, insurers are concerned at growing fire losses, which are at their highest levels since records began, totalling around £3.4m per day.

The use of new materials and modern methods of construction are also resulting in greater volatility to fire.

Blurred lines

However, lines are blurring over where responsibility for fire safety lies through the process of concept, design and installation.

It can change project by project but should in practice lie with the designer along with other specification details, whether they are amended through the development stages or not.

The reality is changing – in a worrying way. Often a steelwork contractor or specialist site fire protection contractor is now expected to take on this responsibility as the project build moves through the process.

They in turn will often rely on other suppliers in the chain for advice such as coatings experts. We at Sherwin-Williams often provide guidance on products to all known standards and are happy to do so as part of our own part in the supply chain.

Ultimately, the responsibility under legislation lies with the ‘Responsible Person’ as described in the Fire Safety Reform Order (2005), which for the purposes of law is referred to as ‘the employer and/or building owners or occupiers.’

They are duty-bound to carry out a fire-safety risk assessment and keep it up to date. This shares the same approach as health and safety risk assessments and can be conducted either as part of an overall risk assessment or as a separate exercise.

Based on the findings of the assessment, employers need to ensure that adequate and appropriate fire safety measures are in place to minimise the risk of injury or loss of life in the event of a fire.

Once they have identified the risks, they can take appropriate action to control them, remove the risk altogether or reduce the risk and manage them. They should also consider how they will protect people if there is a fire.

How is the responsible person to understand and act to cover these issues? Often the only way is to employ fire safety experts – but this comes at a cost.

A worrying trend is emerging where the complexity of fire safe design means it can be out of the responsible person’s sphere of knowledge, and indeed that of steel frame designers or even the fire consultant, where employed – particularly to consider non-structural aspects of fire safety.

Designing structures in the ambient state with no consideration for fire condition is unacceptably risky and irresponsible. Our current industry procedures mean this can easily happen and the burden of ensuring fire safe design, which may well include additional costly measures, is placed with either the wrong party or, in the worse case, missed altogether.

The danger in cutting corners is that fire safety measures will be compromised. We believe the responsibility in modern building design should lie with the designer up to building handover and then, with full knowledge of all fire safety requirements, it becomes the responsibility of the owner/manager.

We believe there is a need for clarity here as building design develops against legislation scoped out some years ago to different design models/codes, particularly in relation to beams with web openings.

The level of protection afforded on any building where large numbers of people move about has to be proportionate to the structure. If this falls short, the time the protection provides for rescue services in the event of a real fire could be reduced and potentially the load bearing capacity of the steel breached much more quickly than anticipated, threatening safe evacuation.

Firetex Design Estimator 2.0

At Sherwin-Williams, we have developed our own piece of software to make sure these calculations are specific and measurable.

For the first time, the software in the new Firetex Design Estimator 2.0 (FDE) offers the capability of providing calculations for all shapes and configurations of apertures within cellular beams as well as efficient handling of unfilled voids with trapezoidal profiled metal decking systems.

Other benefits of this package include project sharing as well as designs to the emerging Eurocodes. The FDE is independently tested and fully verified under the Exova Certifire scheme and, in the case of cellular and fire engineered beams, further verified by the University of Manchester.

Of real interest to the contracting world is that the FDE is also fully building information modelling (BIM) enabled.  Working closely with our partners we  enable our FIRETEX fire protection properties to be fully visualised in the 3D model and available for all stakeholders including QA for application (construction as well as tender bidding) as well as the fire and rescue services and building owners during service.

The estimation and design tool also provides support where a limiting temperature has been specified, useful when a client is working alongside a fire safety consultant for example.

The benefits of best practice in fire safety engineering can be seen as an integrated package of measures within the FDE, designed to achieve the maximum benefit from the available methods of preventing, controlling or limiting the consequences of fire.

Some of those in the supply chain may question why steel parts for new buildings – whether a beam, column or brace for example – would be overly-specified and under-utilised in terms of their load bearing capacity in their ambient design state.

In reality, this performance-based approach allows designers to account for different applied loads being used in various parts of a building for a diverse set of reasons rather than the ‘one-size-fits-all’ prescriptive approach which assumes loads and tolerance.

Dangerous

The trend to assume loads well under the reality of performance-based modelling on each section of steel in today’s complex buildings – thus creating savings for the project in fire protection – is dangerous indeed.

This issue is becoming more complex as designers factor in longer span beams as the pressure to create more letting space becomes more intense.

With more openings and fewer columns, the flexibility of buildings also increases to meet the needs of usage today, with many new steel structures accommodating commercial use as well as living, retail and leisure within the same structure.

Increased knowledge of how real buildings react in fire and of how real fires behave, has led many authorities to acknowledge that improvements in fire safety may now be possible in many instances.

Using modern fire protection design, savings can be made when used professionally and can play a major part in delivering a safe, cost-effective project.

It is the responsibility of the designer working with the fire protection expert to establish the correct level of steel ambient utilisation and with it the appropriate level of protection, amended if needed through the development.

At the heart of fire engineering is safety, no matter how complex and demanding the buildings, in the interests of lives and property.

2023 Fire Safety eBook – Grab your free copy!

Download the Fire Safety in 2023 eBook, keeping you up to date with the biggest news and prosecution stories from around the industry. Chapters include important updates such as the Fire Safety (England) Regulations 2022 and an overview of the new British Standard for the digital management of fire safety information.

Plus, we explore the growing risks of lithium-ion battery fires and hear from experts in disability evacuation and social housing.

FireSafetyeBook-CoverPage-23

Related Topics

Subscribe
Notify of
guest
1 Comment
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
zzth1
zzth1
February 11, 2015 11:55 pm

I feel like the fire protection laws have gotten a lot better and more places are becoming aware of fire safety. I think it is great because it means that we know how to protect ourselves against those types of disasters. It helps when the fire protection is up to date as well. http://www.zaricode.com/